E013—HALL_A Signal failure

(If the motor speed higher than 50rpm, HALL_A is signal keeps continuous 1s low frequency or high frequency, that means the frequency without change for continuous 1s)

Step of solution:
1)check The encoder socket and the main control board  encoder connect
2)check the impedance on encoder board U3—pin 2 to pin 3; around 1.2M;【Standby voltage:follow the angle of raster changing,switch 0V and 5.1V】; impedance【earth】  of U3—pin 4 to pin 3:about 20K.【Standby voltage:1.2V】 ,U3—pin 2 and J1(1pin )is breakover or not.【Remark:when encoder is connecting main control, above impedance is different】
3)Gauge C29 two-terminals impedance on main control board:around 11K ;【Standby voltage:5.1V】; U2(38 pins)or U6—pin 14 to C4 impedance on negative terminal:about 3M【Standby voltage:3.2V】
4)check the C29 two-terminal impedance on main control board: about 11K .(Standby voltage:5.1V); U2(38 pin) or U6-14 pin to impedance on C4 negative terminal: around 3M (Standby voltage:3.2V)
5)check the C39 two-terminal impedance on main control board: about 11K.(Standby voltage:5.1V); U2(52 pins) or U6-18 pins to impedance on C4 negative terminal: 3M detection(Standby voltage:3.2V)
6)check the C41 two-terminal impedance on main control board: about 11K.(Standby voltage:5.1V); U2(64 pins) or U6-7 pins to impedance on C4 negative terminal: around 3M (Standby voltage:3.2V)